Finding · as stated by the study, recorded by Coridum · status verified-machine
Finding F-0085
“Indicatively, indoor exposure in Res_2, with the open fireplace together and the presence of tobacco smokers, PM2.5 levels are considerably high (mean PM2.5 = 137.56 μg/m3).”
Structure
- Source
- Tobacco smoke (secondhand smoke)
- Factor
- Particulate matter (PM₂.₅ and PM₁₀)
- Population
- five patients with asthma or chronic obstructive pulmonary disease (average age 50 years, 40 % male)
- Setting
- home, GR (one year)
- Study design
- panel study: five patients with asthma or COPD monitored over a whole year with 24 h indoor and outdoor PM2.5 measurements, daily peak expiratory flow and biweekly symptom reports (linear mixed effect models, generalized estimating equations) (class 3)
- Effect
- mean 137.56
- Averaging time
- 24 h monitoring over a year
- Sample
- 5 participants
- Caveat
- one residence (Res_2) with an open fireplace and tobacco smokers
A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.