Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-0103

“Among improved stoves, multifuel eco-design had the highest exposure; UFP: 2.2 (4.9) ×104 # cm−3, PM2.5: 14.2 (16.9) μg m−3, PM10: 37.9 (45.9) μg m−3, and BC: 1.5 (2.3) μg m−3 followed by eco-design, and clear skies stage (v) stoves.”

Particulate matter exposure from different heating stoves and fuels in UK homes… (2025). Sci Rep. Page 1. CKB 1154

Structure

Source
Solid fuel
Factor
Particulate matter (PM₂.₅ and PM₁₀)
Setting
home, GB (winter)
Study design
measurement study: indoor UFP, PM10, PM2.5, black carbon and CO measured with handheld monitors in the living areas of five non-smoking households in Guildford using four stove types and four solid fuels during winter (class 4)
Effect
median 37.9
Averaging time
burning periods
Sample
5 households