Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-0156

“For PM10, the highest recorded value is for sieve analysis in the construction material laboratory (1463 μg/m3), and the lowest value is for the proctor compression test (216 μg/m3).”

Zumrut Mitigation strategies to reduce particulate matter concentrations in civil engineering laboratories (2024). Environ Sci Pollut Res Int. Page 5. CKB 1119

Structure

Factor
Particulate matter (PM₂.₅ and PM₁₀)
Population
instructors and civil engineering students
Setting
university laboratory, TR
Study design
measurement study of PM1.0, PM2.5, PM4.0 and PM10 during seven routine experiments in civil engineering laboratories of a university in Izmir, followed by mitigation measures for the three dustiest experiments (class 4)
Effect
other 1463

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.