Finding F-0212

“At foundation stage, the emission factor of TSP, PM10, PM2.5 are 0.0214 g/m2⋅h, 0.0067 g/m2⋅h, 0.0054 g/m2⋅h; at main structure stage, the emission factor of TSP, PM10, PM2.5 are 0.0136 g/m2⋅h, 0.0053 g/m2⋅h, 0.0041 g/m2⋅h; at installation and decoration stage, the emission factor of TSP, PM10, PM2.5 are 0.0165 g/m2⋅h, 0.0059 g/m2⋅h, 0.0043 g/m2⋅h.”

Yang Occupational health risk assessment of construction workers caused by particulate matter exposure on construction sites (2023). Page 1. CKB 0304

Structure

Factor
Particulate matter (PM₂.₅ and PM₁₀)
Population
construction workers
Setting
construction site, CN
Study design
on-site monitoring of particulate matter concentrations at one construction project in Shanghai across construction stages, with emission factors per operating area derived from the monitoring and dispersion simulation, and an occupational health risk assessment for workers (class 4)
Effect
emission-rate 0.0054
Caveat
emission factor derived from on-site concentration monitoring and dispersion modelling of one construction project in Shanghai