Finding · as stated by the study, recorded by Coridum · status verified-machine
Finding F-0213
“At foundation stage, the emission factor of TSP, PM10, PM2.5 are 0.0214 g/m2⋅h, 0.0067 g/m2⋅h, 0.0054 g/m2⋅h; at main structure stage, the emission factor of TSP, PM10, PM2.5 are 0.0136 g/m2⋅h, 0.0053 g/m2⋅h, 0.0041 g/m2⋅h; at installation and decoration stage, the emission factor of TSP, PM10, PM2.5 are 0.0165 g/m2⋅h, 0.0059 g/m2⋅h, 0.0043 g/m2⋅h.”
Structure
- Factor
- Particulate matter (PM₂.₅ and PM₁₀)
- Population
- construction workers
- Setting
- construction site, CN
- Study design
- on-site monitoring of particulate matter concentrations at one construction project in Shanghai across construction stages, with emission factors per operating area derived from the monitoring and dispersion simulation, and an occupational health risk assessment for workers (class 4)
- Effect
- emission-rate 0.0136
- Caveat
- emission factor derived from on-site concentration monitoring and dispersion modelling of one construction project in Shanghai; total suspended particles filed under particulate-matter
A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.