Finding · as stated by the study, recorded by Coridum · status verified-machine
Finding F-0301
“The 95% values of NO2 (0.06 ppm), TVOCs (1066.58 μg/m3 ), and HCHO (176.00 μg/m3 ) exceeded the standard values recommended by the Ministry of Labor, while the 95% values of toluene (265.30 μg/m3 ) exceeded the IAQ guideline values (260 μg/m3 ) recommended by the World Health Organization (WHO).”
Structure
- Factor
- Total volatile organic compounds (TVOC)
- Setting
- office, KR (July to September 2016)
- Study design
- cross-sectional measurement and questionnaire study in 31 offices in Korea (three building groups, July to September 2016): indoor and outdoor air pollutants and subjective symptoms of office workers, with health risk assessment (class 4)
- Effect
- p95 1066.58
- Averaging time
- 95th percentile of the office measurements
- Sample
- 31 rooms
A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.