Finding F-0343

“Compared to casement windows, projecting windows were associated with higher RH (B = 3.61%, p = 0.003), higher PM2.5 (B = 3.17 μg/m3, p = 0.005), and higher HCHO (B = 0.012 mg/m3, p = 0.019).”

Window typology as a determinant of indoor air quality in naturally ventilated tropical African offices (2026). Sci Rep. Page 1. CKB 1116

Structure

Factor
Relative humidity
Intervention
Natural ventilation
Setting
office, NG
Study design
cross-sectional observational study of 54 naturally ventilated government offices in Enugu, Nigeria: CO, CO2, formaldehyde, TVOC, PM2.5 and humidity measured and regressed on window typology (casement, projecting, louvered) with architectural covariates (class 4)
Effect
difference 3.61
Sample
54 rooms