Finding · as stated by the study, recorded by Coridum · status verified-machine
Finding F-0387
“The hourly mean CO2 concentration of indoor (1160 ppm, SD = 604 ppm) was 2.6 times higher than that outdoors (mean = 434 ppm, SD= 60 ppm).”
Structure
- Factor
- Carbon dioxide (CO₂)
- Population
- office employees
- Setting
- office, TW
- Study design
- cross-sectional study of 417 employees in 87 offices in high-rise buildings in Taiwan: 8-hour indoor and outdoor CO2 and TVOC measurements with a sick building syndrome questionnaire, generalized estimating equations logistic regression (class 4)
- Effect
- mean 1160
- Averaging time
- hourly means over 8-hour workdays
- Sample
- 417 participants
A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.