Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-0394

“Adjusted dCO2 prevalence odds ratios for sore throat and wheeze were 1.17 and 1.20 per 100-ppm increase in dCO2 (p <0.05), respectively.”

Indoor carbon dioxide concentrations and sick building syndrome symptoms in the BASE… (2002). Page 1. CKB 0333

Structure

Factor
Carbon dioxide (CO₂)
Outcome
Wheeze
Population
office workers
Setting
office, US
Study design
cross-sectional analysis of the 100-building 1994-1998 USEPA BASE office dataset: workday time-averaged indoor minus outdoor CO2 (dCO2) against sick building syndrome symptoms, multivariate logistic regression adjusted for age, sex, smoking, carpet, thermal exposure and a marker of entrained automobile exhaust (class 4)
Effect
OR 1.20 per 100 ppm
Caveat
prevalence odds ratio; CO2 here is a marker of ventilation rate per person

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.