Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-0399

“Exposure to 2500 ppm CO2 resulted in a significant decrease in the estimated marginal mean of Rotations 13.57 compared with 500 ppm CO2.”

Effects of increasing indoor negative air ions on cognitive performance and health of… (2023). Page 6. CKB 0687

Structure

Factor
Carbon dioxide (CO₂)
Outcome
Cognitive performance
Population
college students
Setting
test chamber, CN
Study design
controlled chamber exposure experiment with college students in Chongqing: 4-hour exposures to 500 ppm and 2500 ppm pure CO2 with and without added negative air ions, cognitive test battery and symptom questionnaires (class 3)
Effect
difference -13.57
Caveat
pure CO2 added to the chamber, not metabolic CO2; the same study tested negative air ions (no Vocabulary slug yet)

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.