Finding F-0534

“Of samples obtained from visually dirty/dusty surfaces, around 98% were below 450 RFU, which is suggested to define the lower-bound for abnormally high levels of mould, rare even on dirty/dusty surfaces.”

Normal background levels of air and surface mould reserve in English residential building stock (2020). UCL open. Environment. Page 1. CKB 5558

Structure

Factor
Mould
Population
households
Setting
dwelling, GB
Study design
surface and activated air sampling of mould reserve quantified by β-N-acetylhexosaminidase (NAHA) activity in 140 residential rooms in England without visible water damage or mould growth, plus a few rooms with visible mould for comparison, to derive background benchmarks (class 4)
Effect
share-below 98
Sample
140 rooms
Caveat
NAHA activity in relative fluorescence units is a proxy for mould reserve; the study proposes benchmarks from the distribution of its own readings