Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-0570

“Similarly, in the indoor exposure model, lower ACT scores were associated with higher indoor NO2 exposure (1.57-points decrease in ACT score per an IQR increase in indoor NO2 exposure; p = 0.017), higher indoor temperature (0.94points decrease in ACT score per 1 °C increase in indoor temperature; p = 0.013), and the presence of mold/dampness (3.09-points decrease in ACT score with the presence of mold/ dampness; p = 0.011).”

Kang Impacts of residential indoor air quality and environmental risk factors on adult asthma-related health outcomes in Chicago, IL (2022). Page 6. CKB 0532

Structure

Source
Dampness and water damage
Factor
Mould
Outcome
Asthma
Population
adults with asthma
Setting
dwelling, US
Study design
Breathe Easy Project pre-intervention period in Chicago: more than one year of data from 53 adults with asthma in 41 homes, quarterly indoor and outdoor pollutant measurements (HCHO, CO, CO2, NO2, O3, PM), home walk-throughs and surveys; asthma control test scores analysed with mixed-effects models, baseline risk factors with adjusted odds ratios (class 4)
Effect
difference 3.09
Sample
53 participants
Caveat
endpoint is the asthma control test score (lower is worse), filed under asthma; the score change is printed as a decrease

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.