Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-0633

“The daily averaged radon concentrations varied from 37 to 573 Bq/m3 for 10 selected workrooms, while hourly averaged radon measurements showed extreme variations from 6 to 1603 Bq/m3 due to radon fluctuations.”

Gulan Radon levels and indoor air quality after application of thermal retrofit measures—a case study (2023). Air quality, atmosphere, & health. Page 1. CKB 8811

Structure

Factor
Radon
Population
office workers
Setting
basement workroom, RS
Study design
case study of radon in workrooms of a thermally retrofitted public building in Serbia: one-month continuous measurement with a digital detector in 10 workrooms during the 2018/19 heating season and charcoal canister measurements in all basement workrooms in spring 2021, grouped by flooring type (class 4)
Effect
other 573
Averaging time
daily averages over one month, heating season 2018/19
Caveat
the sentence gives ranges; the daily ends are recorded as two rows and the hourly range sits in extra

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.