Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-0650

“About 80% of the total measurements of indoor radon concentration exceeded the previous EU reference level of 200 Bq/m3 for new buildings and about 63% exceeded the new reference level of 300 Bq/m3 (Directive 2013/59/EURATOM).”

Assessment of indoor radon levels in Portuguese thermal spas (2016). Radioprotection. Page 5. CKB 0390

Structure

Factor
Radon
Population
spa workers
Setting
thermal spa, PT
Study design
assessment of indoor radon in Portuguese thermal spas with radon measurements in air and in the thermal mineral water (class 4)
Effect
share-above 80

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.