Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-0664

“During intensive monitoring periods, the 405 Monitor measured median 48-h average NO2, NO, and NOx concentrations of 6.0, 9.3, and 9.5 ppb in electric stove homes versus 16.0, 39.7, and 59.1 ppb in gas stove homes, representing reductions of 63%, 76%, and 84%, respectively (all p < 0.001).”

Johnson et al. Characterizing household air pollutant concentrations associated with an electrification program in the rural San Joaquin Valley (2026). Environmental research, health : ERH. Page 5. CKB 6424

Structure

Factor
Nitrogen dioxide (NO₂)
Population
households
Setting
dwelling with an electric stove, US
Study design
comparison of households with electric stoves (electrification programme) and households cooking with natural gas or propane in the rural San Joaquin Valley, California: about one month of personal air monitor measurements and 48 hours with reference-grade instruments in each home, with CO2 above the cooking surface as a stove-use proxy (class 4)
Effect
median 6.0
Averaging time
median 48-hour average

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.