Finding · as stated by the study, recorded by Coridum · status verified-machine
Finding F-0689
“NO2 concentrations were, on average, 1.8 times higher [95% confidence interval (CI), 1.6–2.1] and formaldehyde concentrations were, on average, 9.4 ppb higher (95% CI, 5.7–13.1) dur ing exposure to unflued gas versus flued gas heaters.”
Structure
- Source
- Unvented heaters
- Factor
- Nitrogen dioxide (NO₂)
- Population
- school children
- Setting
- classroom, AU
- Study design
- double-blind, cluster-randomised crossover trial in Australian school classrooms: low-NOx unflued gas heaters against non-indoor-emitting flued gas heaters, NO2 and formaldehyde measured with passive diffusion badges, children recorded symptoms, medication use and lung function twice daily (class 3)
- Effect
- ratio 1.8 (1.6–2.1)
- Caveat
- ratio of concentrations, so the unit is a ratio; the trial randomised heater type by classroom
A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.