Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-0693

“The overall geometric mean NO2 concentration in classrooms was 32 ppb (60.2 μg/m3), and the overall mean concentration of formaldehyde was 29 ppb (35.6 μg/m3) during school hours on the days of measurement.”

Respiratory Health Effects of Exposure to Low-NOx Unflued Gas Heaters in the Classroom: A Double-Blind, Cluster-Randomized, Crossover Study (2010). Environmental health perspectives. Page 4. CKB 6702

Structure

Source
Unvented heaters
Factor
Nitrogen dioxide (NO₂)
Population
school children
Setting
classroom, AU
Study design
double-blind, cluster-randomised crossover trial in Australian school classrooms: low-NOx unflued gas heaters against non-indoor-emitting flued gas heaters, NO2 and formaldehyde measured with passive diffusion badges, children recorded symptoms, medication use and lung function twice daily (class 3)
Effect
median 32
Averaging time
school hours on the measurement days
Caveat
geometric mean recorded under measure median