Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-0818

“The average PM2.5 concentration (μg/m3) was higher in kitchens that burned wood (741.7 ± 546.4) and charcoal (107.0 ± 68.6) than in kitchens where LPG (52.3 ± 18.9) or electricity (52.0 ± 14.8) was used.”

Monitoring and modeling of household air quality related to use of different Cookfuels in Paraguay (2019). Indoor air. Page 1. CKB 7614

Structure

Factor
Particulate matter (PM₂.₅ and PM₁₀)
Setting
kitchen, PY
Study design
cross-sectional monitoring in rural Paraguay: 24-hour time-integrated PM2.5 and continuous carbon monoxide in kitchens that cooked with wood on a three-stone fire, with charcoal in a metal brazier, with liquefied petroleum gas or with electricity, plus questionnaires and multivariable regression models of the two pollutants (class 4)
Effect
mean 52.0
Averaging time
24 h
Caveat
even the gas and electric kitchens stay well above what an emission-free kitchen would show, which the authors attribute to neighbouring households