Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1054

“Compared with international indoor air standards, the total VOC (TVOC) values measured 14–21 days after coating application reached 180.61 ± 60.6 μg/m3 .”

Růžičková et al. Indoor Airborne VOCs from Water-Based Coatings: Transfer Dynamics and Health Implications "2279 (2025). J Xenobiot. Page 20. CKB 1188

Structure

Source
Paints and coatings
Factor
Total volatile organic compounds (TVOC)
Setting
test chamber, CZ (days 14 to 21 after the coating was applied)
Study design
test-chamber study of water-based polyurethane and acrylate-polyurethane lacquers: volatile organic compounds in the coating and in chamber air 14 to 21 days and 60 days after application, with a toxicological grouping of the compounds (class 4)
Effect
mean 180.61
Caveat
the paper also gives 389.33 μg/m3 for the same window with all compounds counted

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.