Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1067

“TVOC concentrations generated from samples B1 (4808 ± 957 μg m–3) and B3 (4140 ± 823 μg m–3), which are the most commonly used KF94 masks for COVID-19 protection, correspond to a high-risk level (health concerns, TVOC = 3000 to 10,000 μg m–3) as established by the TVOC guidelines set by the German Federal Environment Agency concerning Indoor Guide Values (AIR) (der Ad-hoc-Arbeitsgruppe, 2007; Heinzow and Sagunski, 2009; Salthammer, 2011).”

Ryu Measuring the quantity of harmful volatile organic compounds inhaled through masks… (2023). Ecotoxicology and environmental safety. Page 6. CKB 5530

Structure

Factor
Total volatile organic compounds (TVOC)
Setting
test chamber, KR (immediately after the packaging was opened)
Study design
chamber study of the volatile organic compounds released by face masks in Korea: total and individual compounds measured immediately after the packaging was opened, after 30 minutes, after 6 hours and at a raised temperature, for disposable and multi-use masks, with the inhaled mass estimated from the mass flow rate (class 4)
Effect
mean 4808
Caveat
a chamber measurement of the product, not a room concentration

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.