Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1113

“The AOR of high TVOC for CHD was estimated as 5.19 (95% CI: 1.50–17.93) in houses that used smoke ventilators when cooking, and the AOR value tended to be higher in houses without the use of smoke ventilators, but the difference was not statistically significant (AOR 13.1, 95% CI: 0.73–234.81, p = 0.08).”

Association between maternal exposure to indoor air pollution and offspring congenital heart disease: a case–control study in East China (2022). Page 7. CKB 0681

Structure

Factor
Total volatile organic compounds (TVOC)
Population
pregnant women and their newborns
Setting
home, CN
Study design
case-control study in eastern China: indoor total volatile organic compounds, PM2.5 and PM10 measured in the homes of mothers of infants with congenital heart disease and of controls, with logistic regression adjusted for confounders and stratified by recent redecoration and by the use of a cooking smoke ventilator (class 4)
Effect
OR 13.1 (0.73–234.81)
Flags
ci-includes-1
Caveat
the interval spans two orders of magnitude, so the comparison between the two strata carries little weight

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.