Finding · as stated by the study, recorded by Coridum · status verified-machine
Finding F-1215
“Only Inc 5 and Inc 7 show values of benzene below 1 μg/m3.”
Structure
- Source
- Candles and incense
- Factor
- Benzene
- Method
- Emission test chamber method
- Setting
- test chamber, PT
- Study design
- emission chamber study of twelve incense products sold in Portugal: volatile organic compounds, very volatile organic compounds and aldehydes sampled from the chamber by gas chromatography with mass spectrometry and by high performance liquid chromatography, converted through the specific emission rate into a short-term peak concentration and a worst-case time-weighted average for a room of 30 m3, and compared with air quality guideline values (class 4)
- Effect
- share-above 10 per 1 μg/m3
- Sample
- 12 samples
- Caveat
- a count of products, not a share of time or of rooms; the concentration is modelled for a room of 30 m3 from the chamber emission rate, not measured in a room
A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.