Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1233

“Monoterpenes were emitted from the tree at a rate of 12.4 mg h−1 the first day and fell to 1 mg h−1 by day three.”

Poppendieck et al. Jingle bells, what are those smells? Indoor VOC emissions from a live Christmas tree (2024). Indoor environments. Page 1. CKB 6007

Structure

Factor
Monoterpenes
Method
Emission test chamber method
Setting
test chamber, US
Study design
chamber study at the National Institute of Standards and Technology: a freshly cut Douglas fir stood for seventeen days in an environmentally controlled chamber and the volatile organic compounds it emitted were measured continuously with a proton transfer reaction mass spectrometer, with ozone injected on several of the days to observe the indoor chemistry it starts (class 4)
Effect
emission-rate 1
Caveat
one freshly cut Douglas fir in one chamber

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.