Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1243

“In particular, the overall concentration ranges varied greatly, with medians from 38.5 μg/m3 (in HC9) to 79.2 μg/m3 (in HC3) (with an overall median of 49.0 μg/m3).”

Peixoto Assessment of indoor air quality in health clubs: insights into (ultra)fine and coarse particles and gaseous pollutants (2023). Frontiers in public health. Page 8. CKB 5760

Structure

Factor
Ozone (O₃)
Population
users and staff of health clubs
Setting
health club, PT
Study design
measurement campaign in eight health clubs in Porto, Portugal, under the occupancy and ventilation restrictions of the pandemic period: particulate matter as PM10 and PM2.5, particle number concentration between 20 and 1000 nanometres, total volatile organic compounds, carbon dioxide, ozone, temperature and relative humidity measured during occupied periods in the cardiofitness and bodybuilding areas and in the group class studios (class 4)
Effect
median 49.0
Caveat
the clubs had no photocopier, printer or air purifier running during the monitoring, so the study attributes the ozone to outdoor air coming in

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.