Finding · as stated by the study, recorded by Coridum · status verified-machine
Finding F-1246
“In all HCs, TVOCs (0.01–39.67 mg/m3) highly exceeded the existent protection thresholds (1.6–8.9 times) due to the frequent use of cleaning products and disinfectants (2–28 times higher than in previous works).”
Structure
- Factor
- Total volatile organic compounds (TVOC)
- Population
- users and staff of health clubs
- Setting
- health club, PT
- Study design
- measurement campaign in eight health clubs in Porto, Portugal, under the occupancy and ventilation restrictions of the pandemic period: particulate matter as PM10 and PM2.5, particle number concentration between 20 and 1000 nanometres, total volatile organic compounds, carbon dioxide, ozone, temperature and relative humidity measured during occupied periods in the cardiofitness and bodybuilding areas and in the group class studios (class 4)
- Effect
- mean 39.67
- Caveat
- the study attributes the levels to the frequent use of cleaning products and disinfectants under the pandemic rules
A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.