“Emission fluxes EFh obtained with ozone injection ([O3] = ∼10 ppb) were consistently higher than those without (typically [O3] < 1 ppb).”
Structure
- Factor
- Volatile organic compounds (VOCs)
- Method
- Emission test chamber method
- Population
- three adult volunteers
- Setting
- test chamber, CN
- Study design
- single-person chamber experiments with three volunteers at Tsinghua University: emission fluxes of the products of skin oil ozonolysis measured with a proton transfer reaction mass spectrometer with and without ozone injection, while air temperature, relative humidity, bathing frequency, clothing soiling and clothing coverage were varied one at a time (class 3)
- Caveat
- a stated direction without a number; the study reads ozone as the key factor regulating these emissions