Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1298

“For all tested materials, a significant ozone removal was observed: ranging between 8% on a paint and 89% on a pinewood board.”

Nicolas Ozone and indoor air quality - interactions with building products (2006). Page 13. CKB 0003

Structure

Factor
Ozone (O₃)
Method
Emission test chamber method
Setting
test chamber, FR
Study design
doctoral thesis at Universite Paris-Diderot on ozone and indoor air quality: fourteen new and unused building and decoration products were exposed to ozone in a test chamber at controlled temperature and relative humidity over 48-hour experiments, with the ozone removal, the deposition velocity and the share of gas-phase reactions measured for each product (class 4)
Effect
other 8
Caveat
a removal measured on a new and unused product in a chamber, not in a room

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.