Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1302

“Fourteen new and unused products were exposed to 100 – 160 ppb of ozone at 23 °C and 50% RH during 48 hours experiments.”

Nicolas Ozone and indoor air quality - interactions with building products (2006). Page 235. CKB 0003

Structure

Factor
Ozone (O₃)
Method
Emission test chamber method
Setting
test chamber, FR
Study design
doctoral thesis at Universite Paris-Diderot on ozone and indoor air quality: fourteen new and unused building and decoration products were exposed to ozone in a test chamber at controlled temperature and relative humidity over 48-hour experiments, with the ozone removal, the deposition velocity and the share of gas-phase reactions measured for each product (class 4)
Effect
other 14
Caveat
the exposure conditions of the thesis, not a result

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.