Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1303

“On pine wood board, decreasing ozone deposition velocities were measured with increasing ozone concentrations and with relative humidity increasing in the range 30% to 50%.”

Nicolas Ozone and indoor air quality - interactions with building products (2006). Page 235. CKB 0003

Structure

Factor
Ozone (O₃)
Method
Emission test chamber method
Setting
test chamber, FR
Study design
doctoral thesis at Universite Paris-Diderot on ozone and indoor air quality: fourteen new and unused building and decoration products were exposed to ozone in a test chamber at controlled temperature and relative humidity over 48-hour experiments, with the ozone removal, the deposition velocity and the share of gas-phase reactions measured for each product (class 4)
Caveat
a deposition velocity on a new and unused board, not a room concentration

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.