Finding · as stated by the study, recorded by Coridum · status verified-machine
Finding F-1305
“Results and Discussion An increase in the 0.1–0.2 μm particle concentration began in all of the experiments as soon as O3 was introduced into the chamber.”
Structure
- Factor
- Particulate matter (PM₂.₅ and PM₁₀)
- Setting
- test chamber, US
- Study design
- chamber experiments inside an office room: d-limonene was injected into an inner chamber at three levels of relative humidity and ozone was introduced either from a generator or by the natural transport of outdoor ozone into the building, while the particle number and size distribution and the indoor ozone were measured (class 4)
- Caveat
- a stated direction without a concentration; the study had no instrument for particles below 0.1 micrometre
A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.