Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1367

“Only eight of the 166 masses that were enhanced during a professional cleaning event belonged to a compound included in the publicly available ingredient lists or safety data sheet for the cleaning products used during professional cleaning at H2.”

Influence of Cleaning on Indoor Air Concentrations of Volatile and Semivolatile Organic Compounds in Residences (2025). Environmental science & technology. Page 5. CKB 6177

Structure

Source
Cleaning products
Setting
home
Study design
measurement study of cleaning in occupied houses: volatile organic compounds measured continuously by mass spectrometry before, during and after ordinary and professional cleaning events, with the enhanced masses compared against the published ingredient lists and safety data sheets of the products used (class 3)
Effect
other 8
Sample
166 measurements
Caveat
a count of mass spectrometric signals, not of named compounds

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.