Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1379

“Terpenes averaged 7.5 ± 6.7 μg/m3 in the break room, slightly higher than at other indoor sites (0.9 ± 1.0 μg/m3, p = 0.09).”

Lin et al. Occupational Exposure and Health Risks of Volatile Organic Compounds (VOCs) of Hotel Housekeepers Field Measurements of Exposure and Health Risks (2021). Page 8. CKB 0185

Structure

Source
Cleaning products
Factor
Terpenes
Setting
hotel (other indoor sites), US
Study design
measurement study of volatile organic compounds in a hotel in the United States: personal samplers worn by room cleaners, housekeepers, office and maintenance workers together with stationary samples in guest rooms, the laundry room, the lobby, the offices and the break room, and the content of the cleaning products themselves (class 4)
Effect
mean 0.9
Caveat
the sentence prints the spread as a plus-minus value without naming it

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.