Finding · as stated by the study, recorded by Coridum · status verified-machine
Finding F-1426
“Ventilation reduced exposure by approximately 5% per unit increase in air change per hour (ACH), irrespective of whether increases in ACH were by the HVAC system or portable HEPA air cleaners.”
Structure
- Factor
- Ultrafine particles (UFP)
- Intervention
- Air filtration and air purifiers
- Setting
- test chamber
- Study design
- chamber experiments with breathing simulators: personal exposure to respiratory aerosols measured under combinations of ventilation rate, portable high efficiency air cleaners, universal masking, source placement and distance (class 3)
- Effect
- difference 5 per 1 %
- Caveat
- breathing simulators in a chamber, not people in a room
A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.