Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1477

“Simultaneously, the airborne concentrations of plastic additives were determined, with phthalate-based plasticizers having an average concentration of 334 ng m−3 across all air samples.”

Rindelaub Inhalable microplastics and plastic additives in the indoor air of chemical laboratories… (2025). J Expo Sci Environ Epidemiol. Page 1. CKB 1393

Structure

Factor
Phthalates
Study design
study of inhalable microplastics and plastic additives in indoor air: the PM10 fraction sampled indoors and analysed by mass spectrometry for polymer types and for plastic additives (class 4)
Effect
mean 334
Caveat
the additives are measured on the particles of the inhalable fraction, so the gas phase is not included

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.