Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1486

“Finf for the indoor location was 0.30 (95% Confidence Interval [CI] = 0.21 to 0.43) for all study days, 0.30 (95% CI = 0.17 to 0.50) for wildfire days, and 0.40 (95% CI = 0.29 to 0.54) for non-wildfire days.”

Schuller et al. Indoor Air Quality Considerations for Laboratory Animals in Wildfire-Impacted Regions—A Pilot Study (2022). Toxics. Page 6. CKB 8662

Structure

Source
Wildfire smoke
Factor
Particulate matter (PM₂.₅ and PM₁₀)
Setting
laboratory animal facility
Study design
indoor air quality study of a laboratory animal facility: fine particulate matter measured in the room and inside a cage with a high efficiency particulate air filter, indoors and outdoors, on wildfire and non-wildfire days, with the infiltration factor estimated (class 3)
Effect
other 0.30 (0.21–0.43)
Caveat
an infiltration factor between 0 and 1, not a concentration

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.