Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1582

“The concentration of naphthalene vapors (GM 6 μg/m3 , maximum of 20 μg/m3 ) and methylnaphthalenes (GM 8 μg/m3 , maximum of 18 μg/m3 ) was slightly lower in the air of residential buildings.”

Materials contamination and indoor air pollution caused by tar products and fungicidal… (2020). Page 9. CKB 0174

Structure

Factor
Naphthalene
Setting
residential building, PL
Study design
survey of buildings contaminated by tar products and fungicidal preparations: naphthalene and its methyl derivatives measured in the air of public, residential and office buildings alongside the contaminated materials (class 4)
Effect
median 6
Caveat
a geometric mean, recorded here under measure median because the register has no separate value for it; the maximum in the residential buildings was 20 µg/m3

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.