Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1660

“Blink frequency recorded by electromyography was increased during exposure to 0.1 ppm acrolein alone but not during any of the other five exposure conditions.”

Dwivedi Acute effects of acrolein in human volunteers during controlled exposure (2015). Inhalation toxicology. Page 3. CKB 0256

Structure

Factor
Acrolein
Outcome
Eye irritation
Setting
exposure chamber (office-like)
Study design
controlled human exposure experiment: volunteers exposed to acrolein alone and in combination under six conditions, with eye blink frequency recorded by electromyography alongside symptom ratings, lung function, nasal swelling and markers of inflammation (class 2)
Effect
difference
Caveat
the study concludes only minor eye irritation at this concentration, and found no effect on lung function, nasal swelling or the blood and sputum markers

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.