Finding · as stated by the study, recorded by Coridum · status verified-machine
Finding F-1681
“We also observed a decline of 2.2% in FEV1 for every 100 g increase in bedroom dust (p < 0.001).”
Structure
- Factor
- Particulate matter (PM₂.₅ and PM₁₀)
- Outcome
- Lung function
- Setting
- home (bedroom)
- Study design
- integrated model of environmental factors in adult asthma: household allergens, dust mass and antigen-antibody status related to lung function and to an asthma severity score (class 4)
- Effect
- difference 2.2 per 100 g %
- Caveat
- the exposure is the mass of dust collected in the bedroom, not an airborne concentration; the outcome is percent predicted FEV1 and the study says the whole model explains 10% of its variability
A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.