Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1717

“The reduction in the risk of COPD was unequivocal after the fuel and ventilation improvements, with an odds ratio of 0.28 (95% CI, 0.11 to 0.73) for both improvements.”

Lung Function and Incidence of Chronic Obstructive Pulmonary Disease after Improved Cooking Fuels and (2014). PLoS medicine. Page 1. CKB 6888

Structure

Outcome
Chronic obstructive pulmonary disease (COPD)
Intervention
Ventilation
Setting
kitchen
Study design
cohort study of a fuel and ventilation intervention: households replacing biomass with biogas and improving kitchen ventilation followed for lung function decline and for chronic obstructive pulmonary disease (class 3)
Effect
OR 0.28 (0.11–0.73)
Caveat
both improvements together — replacing biomass with biogas and improving the kitchen ventilation — so the two cannot be separated

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.