Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1749

“The overall air nicotine level reduced from 0.59 μg/ m3 GM (95% CI = 0.38-0.91) to 0.48 μg/ m3 GM (95% CI = 0.25-0.93).”

Clearing the air improving smoke-free policy compliance at the national oncology hospital… (2014). BMC cancer. Page 1. CKB 6956

Structure

Source
Tobacco smoke (secondhand smoke)
Factor
Nicotine
Setting
hospital, AM
Study design
before-and-after study at the national oncology hospital in Armenia: indoor fine particulate matter and air nicotine measured before and after a three-part intervention to improve compliance with the hospital smoke-free policy, with staff surveys alongside (class 4)
Effect
median
Caveat
geometric means recorded under measure median; the intervals overlap, so the fall in nicotine is not established by this sentence