Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-1761

“Chemical speciation of the organic aerosol fraction using mass spectrometric data and factor analysis identified a reduced nitrogen component, predominantly found in the indoor environment, contributing 29% of the indoor submicron aerosol mass.”

Thirdhand smoke uptake to aerosol particles in the indoor environment (2018). Science advances. Page 1. CKB 7344

Structure

Source
Tobacco smoke (secondhand smoke)
Factor
Particulate matter (PM₂.₅ and PM₁₀)
Method
Mass spectrometry
Setting
classroom
Study design
measurement study in a university classroom with no modern history of smoking: submicrometre aerosol measured by aerosol mass spectrometry indoors and outdoors, with the organic fraction resolved into components by factor analysis (class 4)
Effect
other 29
Caveat
the component is attributed to tobacco smoke residue by factor analysis of mass spectra, in a room where nobody smokes, and not by a direct measurement of a tobacco marker

A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.