Finding · as stated by the study, recorded by Coridum · status verified-machine
Finding F-0113
“The CADR of the air purifier used in this study was 10.6 m3/min, while the averaged CADRActual at the “house A” was 7.2 m3/min (approximately 66% of the CADR of the air purifier) and 9.5 m3/min at “house B” (approximately 90% of the CADR of the air purifier).”
Structure
- Factor
- Particulate matter (PM₂.₅ and PM₁₀)
- Intervention
- Air purifiers
- Setting
- home, KR
- Study design
- field measurement study: actual clean air delivery rate of one air purifier derived from particle decay rates with and without the purifier over a month in two residential houses of different airtightness (ACH50 4.8 h−1 and 2.1 h−1), at different outdoor PM2.5 concentrations (class 4)
- Effect
- other 7.2
- Sample
- 2 homes
A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.