Finding · as stated by the study, recorded by Coridum · status verified-machine

Finding F-0728

“On average, exposure above 4.1 ppm was associated with an increase in hourly-averaged SBP of 4.3 [1.1, 7.4] mmHg and an increase in hourly-averaged DBP of 4.5 [1.9, 7.2] mmHg as compared to BP following lower CO exposures, adjusted for awake and morning periods.”

Quinn Ambulatory monitoring demonstrates an acute association between cookstove-related carbon monoxide and blood pressure in a Ghanaian cohort (2017). Environmental health : a global access science source. Page 7. CKB 7238

Structure

Source
Cookstoves
Factor
Carbon monoxide (CO)
Outcome
Blood pressure
Population
pregnant women
Setting
personal exposure of the pregnant woman in the household, GH
Study design
sub-study of a randomised cookstove trial in rural Ghana: 24-hour ambulatory blood-pressure monitoring in pregnant women with concurrent personal carbon-monoxide monitoring, analysed by multilevel linear regression with a random intercept for each monitoring session and adjustment for awake hours and the peri-waking period (class 3)
Effect
difference 4.3 (1.1–7.4) per peak carbon monoxide, a two-hour moving average above 4.1 ppm (the 90th percentile of the distribution), against all other exposure mmHg
Sample
20 measurements
Caveat
20 monitoring sessions among 19 women; personal exposure of the woman, not a room concentration