Finding · as stated by the study, recorded by Coridum · status verified-machine
Finding F-1558
“The PM2.5 concentration difference between Advanced and Standard Control was ~ 20% in the kitchen.”
Structure
- Factor
- Particulate matter (PM₂.₅ and PM₁₀)
- Intervention
- Range hoods and kitchen exhaust
- Setting
- kitchen
- Study design
- field comparison of cooking emission mitigation strategies in apartments: an advanced control that runs the stove hood automatically against a standard control where the occupant switches it on, with fine particulate matter logged in the kitchen and in the whole apartment (class 3)
- Effect
- difference 20
- Caveat
- the occupants switched the hood on manually in 66.5 % of the cooking events, for 323.6 hours against 88 hours in the automatic mode
A Finding records what one published document states, verbatim and with its page. It is not a conclusion of Coridum; see the Claims that build on it.