“In this work, the mean bacterial load in the indoor air of all studied wards, OR, and ICU in AMGH taken together was found to be 1914±1081.4 CFU/m3 (95% CI: 1718.5–2109.4 CFU/m3 ).”

Kayta et al. Indoor air microbial load, antibiotic susceptibility profiles of bacteria, and associated factors in different wards of Arba Minch General Hospital, southern Ethiopia (2022). PloS one. Page 12. CKB 8645

Structure

Factor
Airborne bacteria
Method
Air quality monitoring
Setting
hospital ward, ET
Study design
cross-sectional study of hospital wards: bacterial and fungal load of the indoor air determined by the settle plate method in different wards, with the antibiotic susceptibility of the isolates (class 4)
Effect
mean 1914 (1718.5–2109.4)
Caveat
settle plates, a passive method, so the value is a deposition measure converted to a volume concentration