Intervention

Air conditioning

Part of: HVAC systems

Also: air conditioner, air conditioning system, split unit, climate control, cooling

Cooling and dehumidifying indoor air mechanically. Most systems recirculate the air of the room rather than replacing it, so air conditioning changes temperature and humidity — and, through them, several exposures — without in itself providing ventilation.

G-0131 · Updated 16 September 2026 · Coridum Research

What it is

The common misunderstanding is worth stating first: a room air conditioner takes the air of the room, cools it and gives it back. It does not bring in outdoor air, and running it in a closed room does nothing for carbon dioxide or for anything else that ventilation would remove.

What it does change is decisive in its own right. Cooling condenses water, so the relative humidity falls — which suppresses dust mites and mould growth — and the windows stay shut, which lowers the infiltration of outdoor particles in a polluted city. In hot climates these are among the largest effects any indoor measure has.

The cost is where the condensed water goes. Drain pans, coils and ducts that stay wet grow what wet surfaces grow, and a neglected unit becomes the source it was suppressing. Filters in these systems protect the coil, not the occupant, unless they were chosen otherwise.

What the studies report

Linked toEffectPopulationStudy designSourceChecked
Carbon dioxide (CO₂) mean 2470 surgical staff and patients · operating room measurement of particle number concentration (0.3-10 μm) and CO2 in one surgical room with a window/wall air-conditioning system and the adjacent corridor in Brazil during a single surgery and two subsequent surgeries, with outdoor air ventilation calculated from CO2 and compared with the requirement F-0483 Particle and Carbon Dioxide Concentration Levels in a Surgic… (2020) machine
Particulate matter (PM₂.₅ and PM₁₀) mean 22.3 surgical staff and patients · operating room measurement of particle number concentration (0.3-10 μm) and CO2 in one surgical room with a window/wall air-conditioning system and the adjacent corridor in Brazil during a single surgery and two subsequent surgeries, with outdoor air ventilation calculated from CO2 and compared with the requirement F-0484 Particle and Carbon Dioxide Concentration Levels in a Surgic… (2020) machine
Air exchange rate (air changes per hour) other 51 surgical staff and patients · operating room measurement of particle number concentration (0.3-10 μm) and CO2 in one surgical room with a window/wall air-conditioning system and the adjacent corridor in Brazil during a single surgery and two subsequent surgeries, with outdoor air ventilation calculated from CO2 and compared with the requirement F-0485 Particle and Carbon Dioxide Concentration Levels in a Surgic… (2020) machine
Carbon dioxide (CO₂) mean 1433.62 university students · classroom comparison of thirty university classrooms in Brazil, 15 air-conditioned and 15 naturally ventilated: indoor CO2, temperature, relative humidity, wind speed, viable mould and airborne dust measured; values as mean ± standard error F-0521 Jurado et al. Indoor air quality in Brazilian universities (2014) machine
Mould mean 367.00 university students · classroom comparison of thirty university classrooms in Brazil, 15 air-conditioned and 15 naturally ventilated: indoor CO2, temperature, relative humidity, wind speed, viable mould and airborne dust measured; values as mean ± standard error F-0524 Jurado et al. Indoor air quality in Brazilian universities (2014) machine
Atopic dermatitis (eczema) OR 1.57 (1.07–2.30) preschool children · dwelling descriptive cross-sectional online questionnaire study among parents of 964 preschool children in Hail City, Saudi Arabia (July-September 2022), self-administered pre-tested questionnaire distributed on social media, multivariate logistic regression of risk factors for parent-reported diagnosed eczema F-0591 Prevalence and Influencing Risk Factors of Eczema Among Pres… (2022) machine
Radon higher recirculation lowered radon because the recirculated air was already depleted; the dose values are computed, not measured university auditorium occupants · auditorium measurement of radon and its short-lived progeny (attached and unattached fractions) with indoor air parameters in a university auditorium in Lublin, Poland, under different air-conditioning operating modes and recirculation rates F-0641 The influence of air conditioning changes on the effective d… (2016) machine
Radon progeny the dose values are computed, not measured university auditorium occupants · auditorium measurement of radon and its short-lived progeny (attached and unattached fractions) with indoor air parameters in a university auditorium in Lublin, Poland, under different air-conditioning operating modes and recirculation rates F-0642 The influence of air conditioning changes on the effective d… (2016) machine

Each row is one Finding — a sentence as printed in one study, recorded with its page in the Coridum Knowledge Base. Follow the Finding number for the exact wording and the citation. Checked says who verified the row: machine means every automatic check passed and the surrounding text was read; person means someone read the sentence in the document. Rows are re-checked by a person over time. The studies are curated in the Coridum Knowledge Base; the reading of them together is a Claim, shown separately.

Identifiers